|
- 28 April 2006 -
Ferrotec launches upgrades
for e-beam evaporators
At the Society of Vacuum Coaters Conference, Ferrotec (USA)
Corporation, has launched two new major upgrade options for
electron beam (e-beam) evaporation system users: the EV M-10
with smaller spot size and improved beam impact angle; and
the new longer-life e-beam emitter. The EV M-10 also delivers
enhanced operational performance with Ferrotec's new proprietary
High Accuracy Magnetic Field Modeling technology for increased
e-beam precision with smaller spot size and improved beam
impact angle.
The EV M-10 is a high-capacity multi-hearth e-beam source,
a versatile new evaporation platform for large-volume vacuum
chambers. A new high-performance e-beam emitter design, it
is a streamlined component upgrade that delivers enhanced
performance, reliability and system serviceability, says the
company.
"As a market leader for precision electron beam evaporation
systems, Ferrotec is transforming the coating system market
with solutions that deliver unprecedented features, performance,
and value," said Jurgen Pfahler, General Manager of the
Vacuum Solutions Division for Ferrotec GmbH. "From the
EV M-10 high capacity e-beam source to Ferrotec's new emitter
design, our new e-beam products integrate key improvements
that our customers have been requesting."
Typically used for optical coating, electronic, and high-rate
deposition processes, electron beam evaporation systems use
high-voltage (typically 10,000V/500mA) and high-current (typically
50A/12V) to vaporize metals. When the vaporized metal condenses
on a substrate, it forms a thin film coating that can provide
scratch resistance, optical filtering, or other unique performance
characteristics. Ferrotec's new EV M-10 e-beam source - the
assembled subsystem where the evaporation process takes place
- is optimized for volume e-beam coating applications with
an integrated multi-hearth drive-thru assembly that incorporates
optical positioning and water-cooling, large-capacity crucibles,
and flexible support for customer-specified crucible designs.
The new Ferrotec high-performance e-beam emitter is an enhanced
solution for existing Ferrotec customers and some third-party
system users. Designed to provide longer filament life and
to eliminate some of the hassles traditionally associated
with replacing the filament, Ferrotec's new e-beam emitter
uses a streamlined solid ceramic block design with 50% fewer
parts than conventional designs. Because the new design reduces
mechanical variations, customers can get up to twice the filament
life compared to Ferrotec's current e-beam emitter design.
The EV M-10 and the new e-beam emitter are available now.
Both products can be purchased directly from Ferrotec and
through the company's network of electron beam evaporation
sales representatives.
Web: http://www.ferrotec.com/
|